1.
Braz. J. Anesth. (Impr.) ; 73(5): 626-634, 2023. tab, graf
Article in English | LILACS | ID: biblio-1520352

ABSTRACT

Abstract Background: The present study investigated the effects of pulsed and continuous ultrasound (USP and USC) in edema and hyperalgesia after chronic inflammatory process induced by Complete Freund's Adjuvant-CFA and analyzing the relationship of the application frequency of ultrasound, in pro- and anti-inflammatory cytokine production. Methods: Forty-five animals were divided into 9 groups; all animals from groups 2 to 9 were subjected to a persistent inflammation model induced by CFA in mice. We report the effects and the underlying action mechanisms of USP and USC in the animals which were irradiated two, three or five times a week on the left hind paw. The analyses performed in this study were: evaluation of hind paw edema through the plethysmometer, evaluation of thermal hyperalgesia through withdrawal test using a water container at 44.5°C (± 0.5°C), and the plantar region of the left paw which was removed for analysis of cytokines. Results: Our results showed that USP and USC consistently reduced paw edema, and pulsed ultrasound showed a higher significant effect than the continuous mode. Moreover, groups with irradiation frequency of five times a week presented an inhibition of the edema, and groups with frequency of three or two times a week reduced mainly hyperalgesia, in comparison with the control group. The beneficial effects of the US then seem to be associated with upregulation of anti- and pro-inflammatory mediators, such as IL-10 and IL-6, respectively. Conclusion: This study provided evidence that ultrasound constitutes an important non-pharmacological intervention for the management of inflammatory and pain states.


Subject(s)
Rats , Ultrasonic Therapy , Rehabilitation , Edema , Pain Management
2.
Braz. j. phys. ther. (Impr.) ; 16(5): 368-374, Sept.-Oct. 2012. ilus, tab
Article in English | LILACS | ID: lil-654441

ABSTRACT

BACKGROUND: The rapid shallow breathing index (RSBI) is the most widely used index within intensive care units as a predictor of the outcome of weaning, but differences in measurement techniques have generated doubts about its predictive value. OBJECTIVE: To investigate the influence of low levels of pressure support (PS) on the RSBI value of ill patients. METHOD: Prospective study including 30 patients on mechanical ventilation (MV) for 72 hours or more, ready for extubation. Prior to extubation, the RSBI was measured with the patient connected to the ventilator (DragerTM Evita XL) and receiving pressure support ventilation (PSV) and 5 cmH2O of positive end expiratory pressure or PEEP (RSBI_MIN) and then disconnected from the VM and connected to a Wright spirometer in which respiratory rate and exhaled tidal volume were recorded for 1 min (RSBI_ESP). Patients were divided into groups according to the outcome: successful extubation group (SG) and failed extubation group (FG). RESULTS: Of the 30 patients, 11 (37%) failed the extubation process. In the within-group comparison (RSBI_MIN versus RSBI_ESP), the values for RSBI_MIN were lower in both groups: SG (34.79±4.67 and 60.95±24.64) and FG (38.64±12.31 and 80.09±20.71; p<0.05). In the between-group comparison, there was no difference in RSBI_MIN (34.79±14.67 and 38.64±12.31), however RSBI_ESP was higher in patients with extubation failure: SG (60.95±24.64) and FG (80.09±20.71; p<0.05). CONCLUSIONS: In critically ill patients on MV for more than 72h, low levels of PS overestimate the RSBI, and the index needs to be measured with the patient breathing spontaneously without the aid of pressure support.


CONTEXTUALIZAÇÃO: O índice de respiração rápida e superficial (IRRS) tem sido o mais utilizado dentro das unidades de terapia intensiva (UTIs) como preditor do resultado do desmame, porém diferenças no método de obtenção têm gerado dúvidas quanto a seu valor preditivo. OBJETIVO: Verificar a influência de baixos níveis de pressão de suporte (PS) no valor do IRRS em pacientes graves. MÉTODO: Estudo prospectivo, incluindo 30 pacientes sob ventilação mecânica (VM) por 72 horas ou mais, prontos para extubação. Anteriormente à extubação, o IRRS foi obtido com o paciente conectado ao ventilador Evita-XL da DragerTM recebendo pressão de suporte ventilatório (PSV) e PEEP=5 cmH2O (IRRS_MIN) e, logo após, desconectado da VM e conectado a um ventilômetro de WrightTM, onde sua frequência respiratória e o volume corrente exalado eram registrados durante 1 minuto (IRRS_ESP). Os pacientes foram divididos de acordo com o desfecho em grupo sucesso extubação (GS) e grupo insucesso extubação (GI). RESULTADOS: Dos 30 pacientes, 11 (37%) falharam no processo de extubação. Na comparação intragrupos (IRRS_MIN x IRRS_ESP), os valores foram menores para o IRRS_MIN em ambos os grupos: GS (34,79±4,67 e 60,95±24,64) e GI (38,64±12,31 e 80,09±20,71) (p<0,05). Na comparação intergrupos não houve diferença entre IRRS_MIN (34,79±14,67 e 38,64±12,31), por outro lado, IRRS_ESP foi maior nos pacientes com falha na extubação: GS (60,95±24,64) e GI (80,09±20,71) (p<0,05). CONCLUSÃO: Em pacientes graves e sob VM acima de 72 horas, níveis mínimos de PS superestimam o IRRS, sendo necessária sua obtenção com o paciente respirando de forma espontânea sem o auxílio de PS.


Subject(s)
Humans , Middle Aged , Critical Illness , Positive-Pressure Respiration , Respiration , Respiration, Artificial/methods , Ventilator Weaning , Critical Illness/rehabilitation , Prospective Studies